PHD2 Calibration and Troubleshooting

Proper calibration in PHD2 is essential to ensure accurate guiding and optimal performance during imaging sessions. Before starting the calibration process, make sure to configure HelioMaker detection and PHD2 guiding settings. It is highly recommended to verify that object detection is stable over a few guiding samples before initiating calibration. When calibrating on the Moon, it is also strongly recommended to enable Dynamic Target Tracking first, as the correct dynamic lunar rate can substantially reduce drift and improve calibration quality. If the mount is properly polar aligned, this can result in practically no orthogonality error during PHD2 calibration on the Moon. Dynamic tracking may also be useful for solar imaging, although the improvement is usually smaller than for the Moon. For detailed information and examples for setting detection parameters please refer to Find & Track. The same detector interface is used with a shared camera and with a supported physical PHD2 camera. For standalone and fallback physical-camera behavior, see Find & Track with a Physical PHD2 Camera.

Preparing for Calibration

Several factors influence the success and accuracy of PHD2 calibration:

Using Calibration Tools

PHD2 provides several tools to assist with calibration and guiding optimization:

Post-Calibration Optimization

After completing calibration, you can optionally use PHD2's Guiding Assistant (GA) to measure guiding performance and suggest improved guiding settings, such as minimum and maximum motion thresholds. Note the following:

Understanding the PHD2 Calibration Graph

The PHD2 calibration graph shows how the guide target moved while PHD2 sent calibration pulses to the mount. In HelioMaker it is shown in the Session area after valid calibration data is available; until then the plot area may appear empty or dark.

The RA and Dec lines show how the mount axes map onto the camera sensor's X/Y directions. These lines should be roughly perpendicular, but their overall angle on the screen is not important. The calibration points will rarely be perfectly spaced or perfectly aligned. What matters is that the paths are reasonably straight and do not show major curves, sharp turns, or reversals.

Solid points represent the west and north calibration moves used to calculate the RA and Dec guide rates. Hollow points show the return paths for the east and south moves. These return paths are useful for spotting seeing-related fluctuation and mechanical backlash. If the return path looks delayed, offset, or irregular, the mount may have backlash or inconsistent response. If PHD2 is configured to use fast recentering, the return paths may contain fewer points.

Good polar alignment reduces drift during calibration and helps the RA and Dec axes appear clean and orthogonal. A mechanically healthy, well-balanced mount with secure connections and minimal backlash will usually produce a cleaner calibration graph and more reliable guiding corrections.

Calibration quality also depends on an accurate focal length setting in HelioMaker. When the focal length is set correctly, HelioMaker can better estimate the calibration step size and the expected number of calibration points PHD2 should use. An incorrect focal length can make the calibration moves too small or too large, causing PHD2 to complete calibration with too many or too few steps, which can make the resulting calibration graph less reliable.

PHD2 calibration graph

Troubleshooting Calibration Issues

If calibration fails or guiding performance is suboptimal, consider the following: